This new series of FT 900 has a 48 cfm pump and 1200 has a 75cfm pump. When pressing with a vacuclamp vacuum press it is typically done at 165 degrees with a 215 to 225 temperature for pre heat for 60 seconds then press for 90 seconds. The cool down time is 30 to 45 seconds.
If you get dog ears on the corners, increase the temp by 5 degrees and the press time by 10 seconds. If you get wrinkles you typically will reduce the heat and/or time. In general, when giving press assistance Dackor typically starts with the settings you have and then helps you adjust from there to get the best results. Please let us know your settings and what issues you are having by email and we can trouble shoot.